3,509 research outputs found

    Design and implementation of a low-cost phasor measurement unit: a comprehensive review

    Get PDF
    The complexity of the contemporary electrical power systems imposes challenges in aspect of monitoring, protection and control. In order to obtain high speed of response, wide area effect and prices synchronization, the grid control functions can be benefited by the implementation of Phasor Measurement Units (PMU). The paper is aimed to make a review of the commercial implementation of Phasor Measurement Units and then open source based implementations (open architecture hardware and software). This paper focuses on standard implementations; as a consequence the concept of virtual PMU is not discussed here

    Enhancing Grid Reliability With Phasor Measurement Units

    Get PDF
    Over the last decades, great efforts and investments have been made to increase the integration level of renewable energy resources in power grids. The New York State has set the goal to achieve 70% renewable generations by 2030, and realize carbon neutrality by 2040 eventually. However, the increased level of uncertainty brought about by renewables makes it more challenging to maintain stable and robust power grid operation. In addition to renewable energy resources, the ever-increasing number of electric vehicles and active loads have further increased the uncertainties in power systems. All these factors challenge the way the power grids are operated, and thus ask for new solutions to maintain stable and reliable grids. To meet the emerging requirements, advanced metering infrastructures are being integrated into power grids that transform traditional grids into \u27\u27 smart grids . One example is the widely deployed phasor measurement units (PMUs), which enable generating time-synchronized measurements with high sampling frequency, and pave a new path to realize real-time monitoring and control in power grids. However,the massive data generated by PMUs raises the questions of how to efficiently utilize the obtained measurements to understand and control the present system. Additionally, to meet the communication requirements between the advanced meters, the connectivity of the cyber layer has become more sophisticated, and thus is exposed to more cyber-attacks than before. Therefore, to enhance the grid reliability with PMUs, robust and efficient grid monitoring and control methods are required. This dissertation focuses on three important aspects of improving grid reliability with PMUs: (1) power system event detection; (2) impact assessment regarding both steady-state and transient stability; and (3) impact mitigation. In this dissertation, a comprehensive introduction of PMUs in the wide-area monitoring system, and comparisons with the existing supervisory control and data acquisition (SCADA) systems are presented first. Next, a data-driven event detection method is developed for efficient event detection with PMU measurements. A text mining approach is utilized to extract event oscillation patterns and determine event types. To ensure the integrity of the received data, the developed detection method is further designed to identify the fake events, and thus is robust against cyber-threat. Once a real event is detected, it is critical to promptly understand the consequences of the event in both steady and dynamic states. Sometimes, a single system event, e.g., a transmission line fault, may cause subsequent failures that lead to a cascading failure in the grid. In the worst case, these failures can result in large-scale blackouts. To assess the risk of an event in steady state, a probabilistic cascading failure model is developed. With the real-time phasor measurements, the failure probability of each system component at a specific operating condition can be predicted. In terms of the dynamic state, a failure of a system component may cause generators to lose synchronism, which will damage the power plant and lead to a blackout. To predict the transient stability after an event, a predictive online transient stability assessment (TSA) tool is developed in this dissertation. With only one sample of the PMU voltage measurements, the status of the transient stability can be predicted within cycles. In addition to the impact detection and assessment, it is also critical to identify proper mitigations to alleviate the failures. In this dissertation, a data-driven model predictive control strategy is developed. As a parameter-based system model is vulnerable to topology errors, a data-driven model is developed to mimic the grid behavior. Rather than utilizing the system parameters to construct the grid model, the data-driven model only leverages the received phasor measurements to determine proper corrective actions. Furthermore, to be robust against cyber-attacks, a check-point protocol, where past stored trustworthy data can be used to amend the attacked data, is utilized. The overall objective of this dissertation is to efficiently utilize advanced PMUs to detect, assess, and mitigate system failure, and help improve grid reliability

    Low-Resolution Fault Localization Using Phasor Measurement Units with Community Detection

    Get PDF
    A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the observability barrier, they mostly rely on recognizing spatio-temporal patterns, without giving insights on how the performance are tied with the system features and the sensor deployment. In this paper, we try to fill this gap and investigate the limitations and performance limits of fault localization using Phasor Measurement Units (PMUs), in the low measurements regime, i.e., when the system is unobservable with the measurements available. Our main contribution is to show how one can leverage the scarce measurements to localize different type of distribution line faults (three-phase, single-phase to ground, ...) at the level of sub-graph, rather than with the resolution of a line. We show that the resolution we obtain is strongly tied with the graph clustering notion in network science.Comment: Accepted in IEEE SmartGridComm 2018 Conferenc

    A Software-based Low-Jitter Servo Clock for Inexpensive Phasor Measurement Units

    Full text link
    This paper presents the design and the implementation of a servo-clock (SC) for low-cost Phasor Measurement Units (PMUs). The SC relies on a classic Proportional Integral (PI) controller, which has been properly tuned to minimize the synchronization error due to the local oscillator triggering the on-board timer. The SC has been implemented into a PMU prototype developed within the OpenPMU project using a BeagleBone Black (BBB) board. The distinctive feature of the proposed solution is its ability to track an input Pulse-Per-Second (PPS) reference with good long-term stability and with no need for specific on-board synchronization circuitry. Indeed, the SC implementation relies only on one co-processor for real-time application and requires just an input PPS signal that could be distributed from a single substation clock

    Power System State Estimation Using Phasor Measurement Units

    Get PDF
    State estimation is widely used as a tool to evaluate the real time power system prevailing conditions. State estimation algorithms could suffer divergence under stressed system conditions. This dissertation first investigates impacts of variations of load levels and topology errors on the convergence property of the commonly used weighted least square (WLS) state estimator. The influence of topology errors on the condition number of the gain matrix in the state estimator is also analyzed. The minimum singular value of gain matrix is proposed to measure the distance between the operating point and state estimation divergence. To study the impact of the load increment on the convergence property of WLS state estimator, two types of load increment are utilized: one is the load increment of all load buses, and the other is a single load increment. In addition, phasor measurement unit (PMU) measurements are applied in state estimation to verify if they could solve the divergence problem and improve state estimation accuracy. The dissertation investigates the impacts of variations of line power flow increment and topology errors on convergence property of the WLS state estimator. A simple 3-bus system and the IEEE 118-bus system are used as the test cases to verify the common rule. Furthermore, the simulation results show that adding PMU measurements could generally improve the robustness of state estimation. Two new approaches for improving the robustness of the state estimation with PMU measurements are proposed. One is the equality-constrained state estimation with PMU measurements, and the other is Hachtel\u27s matrix state estimation with PMU measurements approach. The dissertation also proposed a new heuristic approach for optimal placement of phasor measurement units (PMUs) in power system for improving state estimation accuracy. In the problem of adding PMU measurements into the estimator, two methods are investigated. Method I is to mix PMU measurements with conventional measurements in the estimator, and method II is to add PMU measurements through a post-processing step. These two methods can achieve very similar state estimation results, but method II is a more time-efficient approach which does not modify the existing state estimation software

    False Data Injection Detection for Phasor Measurement Units

    Get PDF
    Cyber-threats are becoming a big concern due to the potential severe consequences of such threats is false data injection (FDI) attacks where the measures data is manipulated such that the detection is unfeasible using traditional approaches. This work focuses on detecting FDIs for phasor measurement units where compromising one unit is sufficient for launching such attacks. In the proposed approach, moving averages and correlation are used along with machine learning algorithms to detect such attacks. The proposed approach is tested and validated using the IEEE 14-bus and the IEEE 30-bus test systems. The proposed performance was sufficient for detecting the location and attack instances under different scenarios and circumstances

    Study of Inter Area Oscillations Using Phasor Measurement Units

    Get PDF
    Low-frequency oscillations in the power system have major repercussions on power system stability and the objective of maximum power transfer. Local and global control strategies have been developed to dampen and impede these oscillations. A modern local control strategy is supplying the automatic voltage regulation (AVR) of the generator with a power system stabilizer (PSS). Modern global control strategies include supplying the tie lines with flexible alternating current transmission systems devices (FACTS) and a power oscillation damper (POD). Including global signals in conjunction with local signals as an input on the generators PSS has been studied, but follows the same problems as PSSs tuned to enhance damping of the inter-area mode. Once satisfactory results are achieved on the inter-area mode, local modes of the machines involved in the inter-area mode tend to become less stable, or unstable. This type of interaction has caused most of the latest problems regarding damping of the inter-area mode with the use of the generators PSS. The following thesis investigates the impact on inter-area oscillations of including global measurements from phasor measurement units (PMU) in conjunction with local measurements as an input signal on a FACTS-device installed on the tie-line between two interconnected areas. A remote measurement feedback controller has been designed, tuned, and placed on the two-area; four-machine system, created for studying inter-area oscillations. Phasor measurements from optimally located measurement units were shown to improve the damping of the local and inter-area, low-frequency oscillations. The advantages of damping the before-mentioned oscillations were apparent through the ability to increase the power transfer capability in the tie-lines between the two areas following the implementation of the control method. The robustness of the suggested control method was analyzed through a small-signal stability test increasing tie-line power transfer, and a transient stability test using time-domain simulations of a severe fault, more specific a three-phase short circuit on the tie-lines

    Data-Driven Diagnostics of Mechanism and Source of Sustained Oscillations

    Full text link
    Sustained oscillations observed in power systems can damage equipment, degrade the power quality and increase the risks of cascading blackouts. There are several mechanisms that can give rise to oscillations, each requiring different countermeasure to suppress or eliminate the oscillation. This work develops mathematical framework for analysis of sustained oscillations and identifies statistical signatures of each mechanism, based on which a novel oscillation diagnosis method is developed via real-time processing of phasor measurement units (PMUs) data. Case studies show that the proposed method can accurately identify the exact mechanism for sustained oscillation, and meanwhile provide insightful information to locate the oscillation sources.Comment: The paper has been accepted by IEEE Transactions on Power System